T
Description: In-situ measurements of temperature, pressure, relative humidity, rain, solar irradiance and wind (at a temporal resolution of 1 minute) by a Davis Vantage Pro2 weather station named "Davis-001" on the roof of the Erasmus MC building in Rotterdam, The Netherlands, at a height of approx. 112 meters. This station is part of the Rotterdam Atmospheric Measurement Network (RAMN), funded with the help of TU Delft strategic funds, in collaboration with the Ruisdael Observatory. Note: The station was installed on June 13, 2023 but suffered major technical issues during the first two months. It was then damaged during a storm on July 14, 2023 and had to be brought back to TU Delft. As a result, only a few days of observation are available for now.  +
In-situ measurements of temperature, pressure, relative humidity, rain, solar irradiance and wind (at a 1 minute temporal resolution) by a Davis Vantage Pro2 weather station named "Davis-002" at de Zweth in the Netherlands. Situated approximately 7 km to the North West of Rotterdam, and 4 km South East of Delft campus, Zweth is a small town along the Schie river, at the intersection of the historical areas of Delfland and Schieland. The same site also features a micro-rain radar "MRR004_DeZweth" (since February 2022), replaced by "MRR006_DeZweth" (since August 2022) and a Parsivel optical disdrometer "PAR005_DeZweth" (since February 2022). All sensors are placed on top of an air quality monitoring container belonging to TNO, at a height of approx. 4 meters. This station is part of The Rotterdam Atmospheric Measurement Network (RAMN) established with the help of TU Delft strategic funds, in collaboration with the Ruisdael Observatory at TU Delft.  +
In-situ measurements of temperature, pressure, relative humidity, rain, solar irradiance and wind (at a temporal resolution of 1 minute) by a Davis Vantage Pro2 weather station named "Davis-003" at Westmaas, The Netherlands. Westmaas is a village in the Dutch province of South Holland located approximately 15 km south of the city centre of Rotterdam, south of the old Meuse. The same site also features a Parsivel optical disdrometer "PAR004_Westmaas" (since October 2021), and a vertically pointing micro-rain radar "MRR003_Westmaas" (since June 2022). All sensors are placed on top of an air quality monitoring container belonging to TNO, at a height of approx. 4 meters. The container is located approximately 1.5 km to the West of the village of Westmaas, in a predominantly flat and rural area. This station is part of the Rotterdam Atmospheric Measurement Network (RAMN), funded with the help of TU Delft strategic funds, in collaboration with the Ruisdael Observatory.  +
In-situ measurements of temperature, pressure, relative humidity, rain, solar irradiance and wind by a Davis Vantage Pro2 weather station named "Davis-004" at Schiedam. The station is installed on the roof of the DCMR building, at a height of approx. 25 meters. This station is part of The Rotterdam Atmospheric Measurement Network (RAMN), funded with the help of TU Delft strategic funds, in collaboration with the Ruisdael Observatory.  +
In-situ measurements of temperature, pressure, relative humidity, rain, solar irradiance and wind by a Davis Vantage Pro2 weather station named "Davis-005" at Rijnhaven. This station is part of the Rotterdam Atmospheric Measurement Network (RAMN), funded with the help of TU Delft strategic funds, in collaboration with the Ruisdael Observatory.  +
In-situ measurements of temperature, pressure, relative humidity, rain, solar irradiance and wind by a Davis Vantage Pro2 weather station named "Davis-006" at Erasmus University Rotterdam (EUR campus). The station is located on the Sanders building roof, at a height of 29 meters. This station is part of the Rotterdam Atmospheric Measurement Network (RAMN), funded with the help of TU Delft strategic funds, in collaboration with the Ruisdael Observatory.  +
In-situ measurements of temperature, pressure, relative humidity, rain, solar irradiance and wind by a Davis Vantage Pro2 weather station named "Davis-007" at Handelsplein, Rotterdam, The Netherlands. The station is placed on a pole, at a height of 3 meters, with some small nearby trees. This station is part of the Rotterdam Atmospheric Measurement Network (RAMN), funded with the help of TU Delft strategic funds, in collaboration with the Ruisdael Observatory.  +
In-situ measurements of temperature, pressure, relative humidity, rain, solar irradiance and wind by a Davis Vantage Pro2 weather station named "Davis-008" at Platform zero, Rotterdam, The Netherlands. The station is placed on a flat roof, at Galileistraat 33, 3029 AM Rotterdam, at a height of approx. 10 meters. This station is part of the Rotterdam Atmospheric Measurement Network (RAMN), funded with the help of TU Delft strategic funds, in collaboration with the Ruisdael Observatory.  +
In-situ measurements of temperature, pressure, relative humidity, rain, solar irradiance and wind by a Davis Vantage Pro2 weather station named "Davis-009" at Hofbogenpark, Rotterdam, The Netherlands. The station is placed on a roof at Luchtsingel, Raampoortstraat 10, 3032 AH Rotterdam, at a height of approx. 8 meters This station is part of the Rotterdam Atmospheric Measurement Network (RAMN), funded with the help of TU Delft strategic funds, in collaboration with the Ruisdael Observatory.  +
U
Proton-transfer-reaction mass-spectrometer (PTR-MS) at the Loobos site (52°09'59.0"N 5°44'36.4"E). Ambient air is sampled through a ~50m PFA tubing (ID=6 mm, Flow ~10 L/min) from 30 m above the ground (~12 m above the forest canopy). The inlet is located next to a sonic anemometer and the full mass spectra are recorded at 2 Hz.  +
W
10 years of global, direct, and diffuse solar irradiance sampled at 1 Hz as well as fully resolved variability until at least 0.1 Hz from the Baseline Surface Radiation Network (BSRN) station at Cabauw.  +
The Amsterdam Atmospheric Monitoring Supersite (AAMS) contains an eddy covariance flux tower measuring turbulent fluxes of sensible heat, latent heat (evapotranspiration), CO2 and methane, and contains a scintillometer as well. Moreover, we measure up- and downwelling components of the solar and thermal radiation. The data documentation such as stream names, units and instrument type of the Veenkampen can be found in the Excelsheet at the website of https://maq-observations.nl/.  +
This collection contains monthly and annual mean fluxes between 2001-2023 for the various components of the CarbonTracker Europe data assimilation system, for the inversions performed for the GCB2024.  +
A 36 m tall tower is built at the site in 2021, hosting eddy covariance instruments (CO2, heat, evaporation, Volatile Organic Compounds), radiation instruments, profiles of temperature, water vapour, CO2, wind speed. Soil temperature, moisture and heat flux and water table depth measurements are collected around the tower. The data documentation such as stream names, units and instrument type of the Veenkampen can be found in the Excelsheet at the website of https://maq-observations.nl/.  +
Operationally, we measure meteorology, evaporation, CO2 exchange, soil variables and black carbon concentrations. Experimentally, we measure air quality concentrations and fluxes of NOx and NH3. The data documentation such as stream names, units and instrument type of the Veenkampen can be found in the Excelsheet at the website of https://maq-observations.nl/.  +
These are the datasets of the campaigns from CloudRoots and Loobos used in the paper titled 'Tracing diurnal variations of atmospheric CO2, O2 and δ13CO2 over a tropical and a temperate forest'.  +
This dataset is described in detail in: van der Woude et al., Near-real-time CO2 fluxes from CarbonTracker Europe for high-resolution atmospheric modeling, Earth Syst. Sci. Data, 15,, 579–605, https://doi.org/10.5194/essd-15-579-2023, 2023.  +